Tenable Nessus Troubleshooting Plugins
The following plugins can be used when troubleshooting issues with Tenable Nessus.
Tip: Click on a plugin number to view a full description on the Tenable Plugins site.
Plugin Type | Plugin ID | Definition |
---|---|---|
Successful Login (Windows) | 10394 | Microsoft Windows SMB Log In Possible |
10400 | Microsoft Windows SMB Registry Remotely Accessible | |
20811 | Microsoft Windows Installed Software Enumeration (credentialed check) | |
24269 | WMI (Windows Management Instrumentation) Available | |
Successful Login (Linux) | 12634 | Authenticated Check: OS Name and Installed Package Enumeration |
22869 | Software Enumeration (SSH) | |
27576 | Firewall Detection | |
110095 | Target Credential Issues by Authentication Protocol - No Issues Found | |
Successful Login (Windows or Linux) | 141118 | Target Credential Status by Authentication Protocol - Valid Credentials Provided |
122502 | Integration Credential Status by Authentication Protocol - Valid Credentials Provided | |
110095 | Target Credential Issues by Authentication Protocol - No Issues Found | |
Login Failure (Windows or Linux) | 110723 | Target Credential Status by Authentication Protocol - No Credentials Provided |
104410 | Target Credential Status by Authentication Protocol - Failure for Provided Credentials | |
110385 | Target Credential Issues by Authentication Protocol - Insufficient Privilege | |
117885 | Target Credential Issues by Authentication Protocol - Intermittent Authentication Failure | |
122503 | Integration Credential Status by Authentication Protocol - Failure for Provided Credentials | |
21745 | Authentication Failure - Local Checks Not Run | |
24786 | Nessus Windows Scan Not Performed with Admin Privileges | |
10428 | Microsoft Windows SMB Registry Not Fully Accessible Detection | |
26917 | Microsoft Windows SMB Registry: Nessus Cannot Access the Windows Registry | |
91822 | Database Authentication Failure(s) for Provided Credentials | |
11149 | HTTP login page | |
21745 |
OS Security Patch Assessment Failed
Note: This indicates Tenable Nessus is unable to connect to the system, usually for one of the following reasons:
|
|
Nessus Scan Information (All Scans) | 19506 |
Nessus Scan Information
|
112154 |
Nessus Launched Plugin List Note: To use this plugin, you must enable the debug setting. For more information, see Advanced Settings in the Tenable Nessus User Guide.
|
|
Other | 10919 | Open Port Re-Check |
35453 | Microsoft Windows Update Reboot Required | |
35703 | SMB Registry: Start the Registry Service During the Scan | |
35704 | SMB Registry: Stop the Registry Service After the Scan | |
35705 | SMB Registry: Starting the Registry Service during the Scan Failed | |
35706 |
SMB Registry : Stopping the Registry Service after the Scan Failed |
|
84239 | Debugging Log Report |